Winnetka is mostly ranch houses built between the late 1940s and the 1960s. Most of them still have the panel in a hallway closet or on the back wall next to the gas meter. Those panels work, but they are usually full. Before you add a charger, a shop circuit, or a new kitchen, the service deserves an honest look.

DB Electrical — residential panel and meter installation

What we see in Winnetka

Alley garages are the norm. The garage is detached, the run from the house is long, and the circuit feeding it was often added years after the house was built. Put a welder or a chest freezer out there and the wire size matters as much as the breaker.

A lot of homes still have the original 100-amp panel with a split bus. There is nothing wrong with a split-bus panel by itself, but there is no single main to shut everything off, and there is rarely room left for anything new.

Winnetka also has its share of duplexes and small multi-meter buildings. Panel work there is a different job. Each unit has its own service and its own meter, and each one is handled separately.

Replacing a Zinsco or Federal Pacific panel

Both brands show up across the West Valley, and both have a history of breakers that do not trip when they should. If your insurance company is asking for a replacement, they are asking for the panel, not just the breakers inside it.

We replace the panel and the grounding, and we replace any wiring that cannot be reused. If the meter can is the older small style, it usually has to go at the same time so the new service can be connected.

Overhead service and the mast

Most Winnetka houses are fed overhead. When the service is upgraded, the mast and weatherhead often have to be replaced to meet current clearances, and LADWP has to approve the point of attachment before they reconnect.

That approval is not a formality. If the mast is too low or set in the wrong place, the reconnect gets held up. We check it during the estimate, not the morning of the job.

LADWP coordination in Winnetka

Every service change in Winnetka is coordinated with LADWP. They disconnect the existing service, approve the new meter location and point of attachment, and reconnect after the inspection is signed off. We handle the requests and the scheduling. If a new mast or meter can is part of the job, that is spelled out before the work starts so nobody is surprised by a second visit.

What a panel and meter upgrade covers

  • Load calculation and panel schedule before work begins
  • New panel with a single main disconnect
  • Grounding electrode system and bonding to current code
  • Meter can and mast replacement when required
  • LADBS permit, inspection, and corrections
  • LADWP disconnect, point-of-attachment approval, reconnect, and meter set
  • Circuits relabeled and the old panel removed

Questions we get asked in Winnetka

Can you replace a Zinsco or Federal Pacific panel without rewiring the house?

Usually yes. The branch circuits can often be reused if the wire is sound and the insulation is intact. We check the wiring at the panel and in the attic before committing to that. Aluminum branch wiring is a separate conversation.

Does a panel upgrade mean a new meter?

Not always. If the existing meter can is sound and the service size is not changing, LADWP may reconnect to the same can. When the can is old, undersized, or in the wrong place, it gets replaced and LADWP sets a new meter after inspection.

What if the inspection fails?

Then we correct what the inspector flagged and go back. A failed inspection is our problem to fix, not yours. We would rather build it right the first time, but we plan for the correction instead of pretending it cannot happen.

Need this looked at in Winnetka?

Tell us what the house or building is doing today and what you want to add. We will tell you what the service can carry before anything gets quoted.